Comparison of Single versus Double Lateral Plating in Treatment of Feline Ilial Fractures Using Veterinary Cuttable Plates

Authors
Tijn Wiersema, Ties Koolen, Lars F H Theyse, Roelof J Maarschalkweerd, Cornelis D van Zuilen, Sarah J van Rijn
Journal
Vet Comp Orthop Traumatol. 2021 Jun 3. doi: 10.1055/s-0041-1729624.

Objective: The aim of this study was to compare the frequency of implant failure and the extent of pelvic canal narrowing associated with the fixation of ilial fractures in cats with a single veterinary cuttable plate (SLP) or double veterinary cuttable plates (DLP) applied to the lateral surface of the ilium.

Study design: Radiographic evaluation of feline ilial fractures plated laterally using SLP or DLP. Pelvic canal narrowing directly postoperatively and at 6 weeks follow-up was objectively measured using the sacral index (SI). Radiographs were evaluated for implant failure and fracture healing.

Results: Seventy-seven cats satisfied the inclusion criteria. Twenty-nine fractures were treated with a SLP and 48 with DLP. Implant failure occurred significantly more (p = 0.001) in the SLP group (14/29) compared with the DLP group (6/48). Follow-up SI was significantly different between the two groups (p = 0.048, SLP median: 1.0 range: 0.83-2.4, DLP median: 0.98; range: 0.76-1.45). Median change in SI was -0.04 (range: -1.4-0.05) in the SLP group and 0.0 (range: -0.23-0.23) in the DLP group. This difference was significantly different (p = 0.031).

Conclusion: DLP leads to significantly less implant failure and significantly less pelvic canal narrowing compared with SLP. This difference in pelvic canal narrowing was small and the clinical relevance remains unclear.